Syringe pump that can feed constant volume (injection/aspiration)
This seires syringe pumps can assembly 1 or 2 syringes, precision can reach < ± 0.35%. Good performance, high precision and high accuracy. Durable mechanical transmission design, long service life and good reliability.
Screw fixation using special high precision aviation bearing alternatives to traditional copper, longer service life and high precision support for multiple working mode. High resolution color touch screen LCD, simple and easy to set parameters, status display intuitive and clear.
With adjustable protection angencies and alarm mechanism.
The RS-485 communication, support the MODBUS protocol, easy to connect to other devices. All stainless steel shell, easy to clean and maintain.
Model Theparameters |
TYD01-01 | TYD02-01 | TYD03-01 | TYD01-02 | TYD02-02 |
---|---|---|---|---|---|
Work mode | Infusion/withdraw , Infusion/withdraw , withdraw/infusion, continuous mode ; | ||||
Channel number | 1 | 1 | 1 | 2 | 2 |
Stroke of pump pump | 110mm | 140mm | 110mm | 110mm | 140mm |
Pusher advance Per microstep | 0.156um/ustep | 0.156um/ustep | 0.03125um/ustep | 0.156um/ustep | 0.156um/ustep |
Linear speed | 1um/min-150mm/min | 1um/min-150mm/min | 0.2um/min-30mm/min | 1um/min-150mm/min | 1um/min-150mm/min |
Linear resolution | 1um/min | 1um/min | 0.2um/min | 1um/min | 1um/min |
Linear travel accuracy | Error <±0.35% (>30% of pump stroke) ; | ||||
Maximum rated Linear force | > 16kgf | > 20kgf | > 16kgf | > 16kgf | > 20kgf |
Thrust regulation | 1-100% arbitrary adjustable | ||||
Syringe size | 10uL-60mL | 10uL-140mL | 10uL-60mL | 10uL-60mL | 10uL-140mL |
Syringe selection | Built-in main manufactures, the main model syringe to choose; Can use custom syringe, direct input syringe size & diameter; | ||||
Flow calibration | Through the calibration procedure to obtain more accurate fluid volume; | ||||
Display | 4.3 inch color LCD, With screen display and transfusion volume, quantity of liquid, flow, operation direction, syringe specification, etc ; Animation display operation status; | ||||
Operation mode | Touch screen + button | ||||
Power-off memory | Storing the running parameters automatically; | ||||
Other features | Pause and stop; The sound tip; The lock parameters; Fast forward and retreat quickly; | ||||
State signal output | 1 road stop state, 1 state road direction | ||||
Control signal input | 1 road controls the start/stop, 1 road controls the direction; | ||||
Communication interface | RS485, MODBUS protocol; | ||||
Dimensions (LxWxH) | 245x195x133mm | 290x205x140mm | 245x195x133mm | 245x195x133mm | 290x205x141mm |
Weight | 3.2 kg | 4.4 kg | 3.2 kg | 3.2 kg | 4.4 kg |
Applicable power | AC 100-240V/20W | ||||
Working temperature | 5-40℃ | ||||
Relative humidity | > 80% |